PACD011001G2 / PACD011004G3
2.3.2
Main Considerations in Preparation of Control Circuit Diagrams
In addition to the design of the appropriate this system configuration it is also essential that the control
stsyem be made amply clear. If the system is designed and installed without a clear, comprehensive plan
then problems are inevitably going to occur during the test run.
Servicing too will become much more time consuming than necessary. However, if control circuit diagrams
are prepared along with the contract drawings in order to make the total system clearly visible then the
essential points relating to the electrical connections will be easily understood, the test run will go off
without a hitch and the whole system will be rendered fully effective.
Step 1: Compiling a
1. Mark each outdoor unit with a code.
System List
2. Add field settings and data for outdoor units, and outdoor unit No. if using sequential start.
(example using
3. Add the model number of each indoor unit connected to each refrigerant circuit.
MX1 Series)
4. Assign each indoor unit a code.
5. Fill in the location of each indoor unit.
6. Group indoor units controlled by one or two remote controllers. (group or individual control).
7. Assign central group Nos. if using centralized control.
8. Add field settings and optional equipment for indoor units.
9. Add unit No. if making separate field settings for each indoor unit under group control.
Note:
With the Inverter MX1 Series, unit No. is determined through automatic addressing, therefore readout unit
Nos. after activating the power.
Example: System list
Outdoor Unit
Model Name
Field Settings
(code)
Cool/Heat
selector:
Indoor unit
Low noise
operation
(L.N.O.P):
CU-10MX
Individual control
(PAC1)
Sequential start:
ON Defrost:
Earlier
Sequential start
No.
Cool/Heat
selector:
Indoor unit
Low noise
operation
(L.N.O.P):
CU-10MX
Individual control
(PAC2)
Sequential start:
ON Defrost:
Earlier
For details on field settings and centralized control group No., refer to the installation manual and system
reference materials.
Urban Multi Inverter "MX1" Series
Model Name
System Name
CS-32LM
2F01
CS-63LM
2F02
CS-40LM
2F03
CS-63LM
2F04
CS-50LM
2F05
CS-32LM
3F01
CS-40LM
3F02
CS-50LM
3F03
CS-50LM
3F04
Points to Bear in Mind at the System Design
Indoor Unit
Remote
Centralized
Location
Controller
Control Group
Group
2nd floor
A
office
2nd floor
A
office
2nd floor
A
office
2nd floor
B
office
2nd floor
B
office
3rd floor
C
office
3rd floor
C
office
3nd floor
C
office
3rd floor
D
office
Optional
Unit No.
equipment, field
No.
settings, etc.
1–00
(1–00)
(1–00)
1–01
(1–01)
1–02
(1–02)
(1–02)
1–03
9

Advertisement

Table of Contents
loading

Table of Contents