Charge Current Tests - Panasonic KX-TCD725RUM Service Manual

Table of Contents

Advertisement

http://202.224.189.179/view_new/OT/KX-TCD725RUM/SVC/s0806000000.html

8.6 CHARGE CURRENT TESTS

TOP PREVIOUS NEXT
1. Switch on the 9V power supply.
2. Connect an ammeter directly across the charge terminals (effectively short circuiting them).
3. Measure 270mA ± 15% through the meter.
4. Switch off the 9V power supply.
TOP PREVIOUS NEXT
http://202.224.189.179/view_new/OT/KX-TCD725RUM/SVC/s0806000000.html13.10.2007 10:18:41