Changing to the Japanese Language
To change either to or from a Japanese display, do a software download. See the User Manual for Software
Diagnostics Publication No. 636719.
Installing the Developer Filter
[1]
Remove the FILTER CAP and install the new

DEVELOPER FILTER.

[2]
Install the FILTER CAP.
Connecting the Drains
The PROCESSOR can drain developer, fixer, and water separately. The PROCESSOR is shipped with a
separate FIXER OVERFLOW/TANK DRAIN, AUXILIARY FIXER TANK DRAIN, DEVELOPER
OVERFLOW/TANK DRAIN, and AUXILIARY DEVELOPER TANK DRAIN. See Figure ??.
• DRAINS must be made of chemically resistant, non-corrosive material. Use PVC or equivalent.
• The DRAIN must have a minimum diameter of 7.6 cm (3 in.) and be free of obstruction.
• Drain service must comply with all local codes.
[1]
Remove the three 1.9 cm ( ⁄
DEVELOPER, FIXER, and WASH WATER DRAINS on the FEED END of the PROCESSOR.
[2]
Route the tubing as required. Wash water waste can be routed directly to the BUILDING DRAIN. Do
not make a solid connection between the WASH WATER DRAIN and the FLOOR DRAIN.
32
3
in.) HOSES from the PRE-PACK CARTON. Connect the 3 HOSES to the
4
DEVELOPER
FILTER
Figure 38 Installing a New
FILTER
CAP
H108_0068ACA
H108_0068AA
Developer Filter
1C0932