Grounding Lug - Kodak X-Omat 480 RA Processor Installation Instructions Manual

Hide thumbs Also See for X-Omat 480 RA Processor:
Table of Contents

Advertisement

Connecting the Jumpers at
Terminal Strip TB2
[1]
Remove the FEED-END LOWER ACCESS
PANEL from the PROCESSOR.
[2]
Open the TRANSFORMER BOX COVER.
[3]
Determine the supply voltage to be applied to
the PROCESSOR.
[4]
Using the ''Supply Voltage Connection
Tables'' and the ''Diagrams for Terminal Strip
TB2'' on pages ?? through ??, do the
following to make the connections:
(a)
Connect the METAL JUMPERS.
(b)
Connect the WIRE JUMPERS.
The METAL JUMPERS and WIRE
JUMPERS are provided in the
PRE-PACK CARTON.
[5]
Route the wires neatly so that the wires do
not become pinched or scraped when the
TRANSFORMER BOX COVER is closed.
Connecting the Wiring to the Terminal Strip TB1
Dangerous Voltage
[6]
Move the wall power switch to the ''OFF''
position.
[7]
Using the ''Supply Voltage Connection
Tables'' on pages ?? through ??, connect the
main input power wires to TERMINAL STRIP
TB1 and to the GROUNDING LUG. Wiring
must meet all local codes.
[8]
Close the TRANSFORMER BOX COVER.
[9]
Install the FEED-END LOWER ACCESS
PANEL onto the PROCESSOR.
22
Connecting the Processor
NOTE
CONDUIT
GROUNDING
LUG
TB2
TRANSFORMER
BOX COVER
Figure 27 Transformer Box Interior
TBI
H108_0056CCA
H108_0056CA
1C0932