7.5.5 DSI PLL Controller Basic Programming Model
7.5.5.1
Software Reset
The DSI PLL control module does not have its own software reset. It is reset by the DSI protocol engine.
Nevertheless, software users can monitor the reset status of the DSI PLL control module by reading the
DSS.DSI_PLL_STATUS[0] DSI_PLLCTRL_RESET_DONE status bit.
7.5.5.2

DSI PLL Programming Blocks

Figure 7-135
shows the DSI PLL programming blocks.
PCLK
SYSCLK
PMP
SCP
SCPBusy
UPDATE
SYNC
SWPU177N – December 2009 – Revised November 2010
Public Version
Figure 7-135. DSI PLL Programming Blocks
PLL
Reference
Go bit
DSI_PLLCTRL
Copyright © 2009–2010, Texas Instruments Incorporated
Display Subsystem Basic Programming Model
CLKINP
PMP
SYSRESETs
FSM
Configuration
values
TINITZ
GO
etc.
FSM
Display Subsystem