Powering Off Procedures For Powerstore Appliances; Power Off A Powerstore T Model Appliance; Powering On Procedures For Powerstore Appliances - Dell PowerStore 500T Installation And Service Manual

Hide thumbs Also See for PowerStore 500T:
Table of Contents

Advertisement

3. Based on the node you are logged into, run one of the following commands:
● svc_node reboot local to reboot the node you are logged into.
● svc_node reboot peer to reboot the peer node.
For more information, see the PowerStore Service Scripts Guide.

Powering off procedures for PowerStore appliances

This section includes the following procedures:

Power off a PowerStore T model appliance

Power off a PowerStore T model appliance
Prerequisites
● Do not power off the appliance if you are replacing a hardware component. Identify the node that includes the faulted
hardware component, and power off only that node. For more information, see
PowerStore Manager
● Powering off an appliance results in the mapped hosts losing access to the data on the appliance. Before you begin, ensure
that you temporarily disconnect host access from all storage resources.
● Obtain the following information:
○ Management IP address of the appliance. In PowerStore Manager, go to Settings > Networking > Networking IPs >
Management. Review the Management IPs table to identify the management IP address associated with the appliance.
○ Service account credentials
○ Service tags of the appliance
About this task
Use the following procedure to power off a single PowerStore T model appliance.
To power off all of the appliances in a cluster, see
Steps
1. Log in to PowerStore Manager.
2. Under Hardware, select the appliance that you want to power off.
3. Under More Actions, select Power Down.
The Validation window opens.
4. Review any errors, warnings, and recommendations. Once the appliance passes all of the validation checks, click Next.
The Active Objects window opens.
5. Review the list of objects on the appliance that had I/O activity during the last five minutes.
6. Click Next.
The Confirm window opens.
7. Enter the service password, and click Power Down.
8. Check the status of the LEDs in the rear of chassis to verify that the appliance has powered off. Other than the LEDs for
the power supply unit, management port, and service port, all other LEDs on the appliance must be OFF.
9. Wait five minutes, and then disconnect the power cables from the base enclosure.

Powering on procedures for PowerStore appliances

This section includes the following procedures:
Power on a PowerStore T model appliance
60
Power control procedures
on page 60
on page 57.
Power off a PowerStore T model cluster
on page 61
Power off a PowerStore T model node using
on page 61:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents