Rebooting procedures for a PowerStore node
This section includes the following procedures:
●
Reboot a PowerStore T model node using PowerStore Manager
●
Reboot a PowerStore T model node using a service script
Reboot a PowerStore T model node using PowerStore Manager
Prerequisites
Obtain the following information:
● Management IP address of the cluster to log in to PowerStore Manager
● PowerStore Manager user account credentials with administrator privileges
NOTE:
Do not power off or reboot a node, if the peer node is not operating normally. If the peer node is experiencing any
major issues, associated alerts and events appear in PowerStore Manager.
Also, to avoid service interruptions, ensure that there are sufficient and healthy paths from all connected hosts to the peer
node.
About this task
Use the following procedure to reboot a PowerStore T model node using PowerStore Manager:
Steps
1. Under Hardware, select the appliance that includes the node you want to power off.
2. On the Appliance Details page, select the Components card.
3. On the Components card, under Rear View, expand Base Enclosure, and then select the node that you want to power
off.
4. Under More Actions, select Reboot.
5. On the confirmation prompt, enter the service password, and then click Reboot.
Reboot a PowerStore T model node using a service script
Prerequisites
Obtain the following information:
● Management IP address of the appliance that contains the node. In PowerStore Manager, go to Settings > Networking
> Networking IPs > Management. Review the Management IPs table to identify the management IP address associated
with the appliance.
● Service account credentials
NOTE:
Do not power off or reboot a node, if the peer node is not operating normally. If the peer node is experiencing any
major issues, associated alerts and events appear in PowerStore Manager.
Also, to avoid service interruptions, ensure that there are sufficient and healthy paths from all connected hosts to the peer
node.
About this task
Use the following procedure to reboot a PowerStore T model node using a service script:
Steps
1. Launch an SSH client, and connect to the appliance using the management IP address.
2. Enter the username and password for the service account to log in.
The login prompt indicates the node that you are logged into. For example, the letter "A" in the prompt
[SVC:user@FNM12345678910-A~]$ indicates that you are logged into node A.
on page 59
on page 59
Power control procedures
59