Kenwood NX-220 Service Manual page 70

Hide thumbs Also See for NX-220:
Table of Contents

Advertisement

NX-220
Item
Panel tuning mode
Maximum
1) Adj item: [NDEV]
Deviation
Adjust: [✳✳✳✳]
(NXDN) *3
2) Adj item: [N.DEV_]→
[N.D.EV_]→[N.D.E.V_]→
[Very
[N.D.E.V._]→[N.D.E.V._.]
Narrow]
Adjust: [✳✳✳✳]
PTT: ON
Press [
] key to
store the adjust-
ment value.
5. Maximum
1) Adj item: [ADEV]
Deviation
Adjust: [✳✳✳✳.]
(Analog) *3
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
2) Adj item: [A.DEV_]→
[A.D.EV_]→[A.D.E.V_]→
[A.D.E.V._]→[A.D.E.V._.]
Adjust: [✳✳✳✳.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [ADEV]
Adjust: [✳✳.✳.✳.]
2) Adj item: [A.DEV_]→
[A.D.EV_]→[A.D.E.V_]→
[A.D.E.V._]→[A.D.E.V._.]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
*3: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on pages 76 and 78.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
6. QT
1) Adj item: [QT]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [QT]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
70
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Very Narrow)]
Oscilloscope
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [QT
Deviation
Deviation (Analog
meter
Narrow)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Analog Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
ANT
Panel
Adjustment
Specifi cations /
Parts
Method
[Panel
1337Hz
1311~1363Hz
tuning
Write the value as
mode]
followings.
[PC test mode]
Selector
513 (Reference
Press [Apply All]
value)
button to store the
[PC test
adjustment value
mode]
after all adjustment
[ ],[ ]
points have been
adjusted.
2100Hz
2050~2150Hz
Write the value as
followings.
[PC test mode]
513 (Reference
Press [Apply All]
value)
button to store the
adjustment value
after all adjustment
points have been
adjusted.
4200Hz
4150~4250Hz
Write the value as
followings.
[PC test mode]
513 (Reference
Press [Apply All]
value)
button to store the
adjustment value
after all adjustment
points have been
adjusted.
[Panel
Write the value as
0.35kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
0.75kHz±0.05kHz
Remarks

Advertisement

Table of Contents
loading