Indoor Fan Motor Control - Toshiba RAS-25E2KVG-ND Service Manual

Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ °C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Fan speed
Mode
level
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WC)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4
*4 : Fan speed = (M + –L) x 2/4 + L
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W7)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-25E2KVG-ND
Cooling
Dry
Fan speed Air flow rate Fan speed Air flow rate Fan speed Air flow rate Fan speed Air flow rate
3
(rpm)
(m
/h)
718
1100
718
1100
702
UH
1080
596
H
940
900
566
M+
488
M
800
400
700
378
L+
670
261
520
520
261
L
470
236
L-
450
230
UL
450
230
SUL/SL-
230
450
450
230
(Fig. 1)
Fan speed
W7
(L + M) / 2
WA
(M + H) / 2
WD
(Fig. 2)
Heating
3
(rpm)
(rpm)
(m
/h)
1180
781
1150
1150
758
1150
1000
638
1120
604
950
980
850
527
900
750
450
850
690
392
750
540
275
670
500
247
520
500
247
520
500
247
500
247
500
500
480
240
500
240
480
450
480
240
450
- 28 -
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
RAS-35E2KVG-ND
Cooling
Heating
3
(rpm)
(m
/h)
758
1300
758
1270
734
1150
624
1050
566
930
527
790
700
450
378
550
261
500
261
500
247
500
247
500
247
480
230
480
230
480
3
(m
/h)
870
850
758
680
588
480
400
283
247
247
247
247
240
240
240