Note: The screws are not supplied with the device. The type and length of the screws depend on
the type of wall.
Screwing the Cover Plate to the Mounting Plate for the Cable
Feedthrough
The cabling of the Enterasys Wireless Outdoor AP is led out of the rear of the device. The housing
seal is effective only when it is not subjected to spray water. If the device is mounted on a wall, no
further measures are necessary. When mounted in any other way, an additional cover plate must
be screwed to the mounting plate.
Warning: If the cable feedthrough on the rear of the device is exposed to spray water, degree of
protection IP65 no longer applies. In this case, water can penetrate the device and establish a live
connection to the line voltage. There is then a risk of electric shock. Ensure that you use the cover
plate for the cable feedthrough if you are not mounting the Enterasys Wireless Outdoor AP on a
wall.
To screw the cover plate to the mounting plate for the cable feedthrough:
1.
Fit the cover plate on the mounting plate from below until the two lugs (Position A in
Figure
2‐8) engage the lower edge of the mounting plate.
Figure 2-8
2.
Secure the cover plate to the mounting plate with two M4 screws. The screws are supplied
with the assembly kit.
Fitting and Securing the Cover Plate for the Cable Feedthrough
Mounting the Enterasys Wireless Outdoor AP with Mounting Plate