7.4 Connecting GOT and Inverter via PLC (Ethernet)
This sample screen can also be used for connecting GOT2000 and MELSEC iQ-R/Q/L series PLC via Ethernet and
then connecting the PLC and the inverter*1 via Ethernet interface unit.
The setting example for connection via MELSEC iQ-R CPU and the Ethernet interface unit is as below.
*1: For the FR-E800-E inverter
System Configuration
GOT2000
・ GT27**- V(640×480)
・ Interface:
Standard I/F (Ethernet)
(Network No.1, Station No. 18,
IP: 192.168.3.18)
*1: For more details on the cable, please refer to "GOT2000 Series Connection Manual (Mitsubishi Products)".
Ethernet cable*1
・MELSEC PLC (RCPU/QCPU/LCPU)
(Network No.1, Station No. 1, IP: 192.168.3.39)
+
・Ethernet unit
(Network No.2, Station No. 40, IP: 192.168.4.40)
・FR-E800-E
・Interface: Ethernet
(Network No.2, Station No. 1,
IP: 192.168.4.50)
66/79
Ethernet cable*1
Motor
BCN-P5999-1305-1c