7.5.3

Inverter FR-E800-E Communication Settings

Set the parameters of the communication settings with PU (operation panel or Parameter unit). An inverter reset
after the setting is required for the parameters of the communication settings.
Item
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
Ethernet function selection 4
Ethernet IP address 1
Ethernet IP address 2
Ethernet IP address 3
Ethernet IP address 4
Subnet mask 1
Subnet mask 2
Subnet mask 3
Subnet mask 4
*1: Settings of the GOT can be changed. When changing the settings, also change the settings of the inverter.
*2: Change the settings depending on the operation environment.
7.5.4

Settings of Sample Screen

Station Number Switching
In this sample screen, station No. can be switched between 1 and 16 in the default setting. When switching to the
number other than 1 to 16 such as station number 17, please refer to "7.7
Station No.
" and change the settings according to the system configuration.
7.5.5

Precautions

When connecting GOT2000 to the inverter via CC-Link IE TSN, the value cannot be written to the link devices (RX,
RY, RWw, RWr) which the functions (signals) are assigned to by GOT.
Forward command is assigned to RYn0, and reverse command is assigned to RYn1. Therefore forward/reverse
command cannot be input by [Forward] and [Reverse] switches in the operation command screens (B-12120 and
B-12121) and [Auto measure] switch in [
Change the link devices (RX, RY, RWw, RWr) of the master station to control the link devices (RX, RY, RWw, RWr)
value.
The screens below have the limitations in this sample screen.
B-12120, B-12121
B-12310
For the functions (signals) assigned to the link devices, please refer to "INVERTER FR-E800 Instruction Manual
(Communication)".
Parameter
Pr.1427
Pr.1428
Pr.1429
Pr.1430
Pr.1434
Pr.1435
Pr.1436
Pr.1437
Pr.1438
Pr.1439
Pr.1440
Pr.1441
Machine diag.(load char. meas.)
Screen
Set Value
45237 (Default value)
45238 (Default value)
0 to 255
255 (Default value)
255 (Default value)
255 (Default value)
0 (Default value)
[Forward] or [Reverse] cannot be performed.
[Auto measure] cannot be performed.
72/79
5001
9999
*1
*1
*2
*1
*2
*1
*2
*1
*2
Changing the Inverter Network No. and
] screen (B-12310).
Limitations
BCN-P5999-1305-1c
Remarks