Basic principle
All devices at the TCS:BUS
When programming a bell button, the serial number is allocated to an indoor station and
is stored in the EEPROM of the front-door station. Per bell button 1 or 2 indoor stations
(serial numbers) can be allocated and called.
If no serial number is allocated to a bell button (delivery state: deleted), lights can be
switched by pressing this button.
Manual programming of a bell button
Ensure that the indoor station at the TCS:BUS
switched on (the LED at the power supply and control unit is on).
Notes:
Before an already programmed bell button can be programmed anew, the program-
ming has to be deleted.
The AS addresses of the bell button modules and of the built-in door loudspeaker
module resp. display module must be identical to establish a connection:
!
Adjust the AS addresses to the same value and block the addresses.
The AS addresses of the bell button module AMI1090x can only be adjusted with the
configuration software configo
Protocol digit when setting via TCSK-01: *76 # SNr. # AS #.
Legend
press button shortly
press button until
release button
ring tone
period (e.g. 6 sec)
1
power supply and control unit
Shortly press the
RUN/PROG button
TCS TürControlSysteme AG, TCS Hotline Deutschland: hotline@tcsag.de
www.tcsag.de
Programme bell buttons
®
have a unique serial number.
TM
◄6s►
Initiate
Switch off the programming mode of the system
LED blinks
6
®
is connected and the mains voltage is
or the Service Device TCSK-01.
negative acknowledge-
ment (name plate blinks
fast 5x)
positive acknowledgement
(name plate is on shortly,
then blinks again)
Progsperr tone
repeat
continue
Nameplate of the bell button module blinks.
Programming mode of the system is switched on.
01/2013
Subject to technical changes.
PI_AMI1090x-uk 1A