  • Page 1 USPA 6800 U OWNER’S MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PRODUCT INFORMATION Important Safeguards..........4 Safety Information............6 Cautions Before Installation.........8 Main Unit & Parts............12 PRODUCT INSTALLATION Installation..............14 Operation..............18 PRODUCT SETTINGS Cleaning...............26 Maintenance...............28 Troubleshooting............30 Specifications............32 WARRANTY Warranty..............34...
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS READ ALL OPERATING INSTRUCTIONS BEFORE INSTALLATION WARNING - To reduce the risk of burns, electric shock, fire, or injury. NOTES 1. Close supervision is necessary when this appliance is used by or is near infants, elders, or handicapped persons. Children should not be 1.
  • Page 4: Safety Information

    SAFETY INFORMATION (DANGER) SAFETY INFORMATION (WARNING) DANGER - FOLLOW THESE BASIC INSTRUCTIONS TO ENSURE WARNING - FOLLOW THESE BASIC INSTRUCTIONS TO ENSURE THE SAFE USE OF YOUR APPLIANCE. THE SAFE USE OF YOUR APPLIANCE. • • Do not use a faulty or loose electric outlet or cord. Do not step on or place heavy objects on this appliance.
  • Page 5: Cautions Before Installation

    CAUTIONS BEFORE INSTALLATION NOTE THE FOLLOWING IMPORTANT POINTS WIRING REQUIREMENTS 1. Do not install in a location where water might be splashed on this 1. After installation, all other servicing should be performed appliance or in a location exposed to excessive moisture where by authorized service representatives.
  • Page 6 CAUTIONS BEFORE INSTALLATION (CONT.) 3. This product is for use on a nominal 120V circuit. It has a grounding plug that is similar to the plug illustrated in sketch A. A temporary adapter, which looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available.
  • Page 7: Main Unit & Parts

    MAIN UNIT & PARTS 15mm Water supply hose (2pcs) (7/8” to 3/8” and 1/2” to 1/2”) T-valve...
  • Page 8: Installation

    INSTALLATION CAUTION - Do not plug in until installation is finished. Mounting the Plate Not doing so may damage the appliance. Place the mounting plate over each If electric work is needed, please contact a qualified mounting hole. Insert the mounting bolts through the plate and mounting electrician or serviceman only.
  • Page 9 INSTALLATION (CONT.) Connecting the Water Hose Trial Operation 1. Preparation Connect the other end of the flexible hose from the T-valve to the main appliance. Plug the power cord into the outlet, and then the water tank will be filled in 2 minutes. Using Inline Carbon Filter - The use of an external inline carbon water filter 2.
  • Page 10: Operation

    OPERATION • Press “Dry” Warm air will come out for 3 minutes. • To alter the strength of drying, press the button again. • Dry temperature can be adjusted by pressing LOW or HIGH on the back of the remote button to 5 levels. Cleansing •...
  • Page 11 OPERATION (CONT.) Temperature Adjustment (Water/Seat) Water Pressure (Cleansing/Bidet) • • The temperature of seat and water can be adjusted by Water spray pressure can be adjusted by pressing pressing button located on the back of the remote. LOW or HIGH button to 5 levels. •...
  • Page 12 OPERATION (CONT.) User Setting Identification • • Each button can save 2 settings. (Cleansing, Bidet) This function is useful for public toilets when more than one unit of this product is installed. • Press the User 1 button and Cleansing or Bidet consecutively. Then •...
  • Page 13 OPERATION (CONT.) Set the Unit • Unplug the unit and then plug it back in. • Push the power bidet button on the side of the unit to turn the unit off. • Push the button again and this time hold it down (It should turn on when you do this).
  • Page 14: Cleaning

    CLEANING Strainer Maintenance CAUTION: Do not forcefully push, pull, or bend the nozzles. It may result in failure. Make sure to use the “Stop” button on • This appliance will not operate properly if the strainer is clogged. the remote control. Be sure to clean the strainer regularly.
  • Page 15: Maintenance

    MAINTENANCE Draining Water - while not using it over extended period of time. Unplug the Power Supply Cord. • Refer to the trial operation method in order to Unplug the Power Supply Cord. use this appliance again. • Not doing so may cause electric shock or fire.
  • Page 16: Troubleshooting

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION 1. Power outage 1. Reset the GFI outlet. Unit Water 1. Self-cleaning 1. The unit will self-clean the 2. The unit is not plugged in. 2. Plug the power cord in to a completely coming out nozzle before and after each...
  • Page 17: Specifications

    SPECIFICATIONS ITEM UB-6800U/UB-6800US Standard power supply AC 120V 60Hz 660W Water Supply Way of connection Direct connection to tap water Water pressure 0.07 MPa ~ 0.74 MPa Cleansing Spray for cleansing 900 (±100) ml/min Spray for bidet 900 (±100) ml/min Water capacity 800 ml Spray temperature...
  • Page 18: Warranty

    WARRANTY USPA Personal Hygiene Appliance Limited Warranty This limited warranty is our only warranty covering your product. Repair or replacement as provided under this warranty shall be the exclusive remedy We warrant our products to be free from manufacturing defects under normal available to you.