ESP
TCP

Control and Safety Sensors

ESP
The ESP (Exhaust Sensing Probe) is a temperature
sensing probe located in the exhaust outlet. The
ESP works with the Control to perform all burn
rate functions as well as high and low limit
control.

Room Sensor

The Room Sensor is a small temperature sensor
placed where you would normally put a thermo-
stat. The Room Sensor is extended to the stove
with normal thermostat wire. The Room Sensor
works with the ESP and the Control to provide
the right size fire.
FSS
The FSS (Firebox Static Switch) is an electronic
pressure switch that senses firebox pressure. The
FSS works with the ESP Control to adjust the draft
blower speed to compensate for wind and changing
house pressures.
TCP
The TCP (Temperature Control Probe) is located on
the left side of the feeder. The TCP works with the
Control to reduce the feeder temperature if the
temperature begins to rise.