Wiring of sensor connector (e-CON)
Applicable connector
Prepare sensor connectors (e-CON) separately.
The following table lists reference products of connectors.
Model
Manufacturer
ECN-M014R
Mitsubishi Electric System & Service Co., Ltd.
ECN-M024Y
ECN-M034OR
ECN-M044GN
ECN-M054BL
ECN-M064GY
Signal name and wiring
For the signal names of the terminal block and wiring of the external device, refer to the specifications of each module. (
Page 22 Performance Specifications)
Incorrect wiring can cause malfunction of or damage on the module.
Wiring method
For how to wire the sensor connectors (e-CON), refer to the catalogs of each manufacturer.
6 INSTALLATION AND WIRING
146
6.9 Wiring of I/O Module and External Device
Specifications
Applicable cable
Applicable cable
(core wire size)
(outer diameter)
0.8 to 1.0mm
0.14 to 0.30
(26 to 24 AWG)
1.0 to 1.2mm
1.2 to 1.6mm
1.0 to 1.2mm
0.30 to 0.50
(22 to 20 AWG)
1.2 to 1.6mm
1.6 to 2.0mm
Color of the
cover
Maximum
rated current
2.0A
Red
Yellow
Orange
Green
Blue
Gray