Bosch Rexroth AG
Mounting, demounting and electric installation
Pin
Function
9
S3 (black key) N/O contact
10
S3 (black key) N/C contact
Tab. 9-8: Pin assignment X3
NOTICE
For terminal connectors use copper wire only. Tighten the screws of the screw
terminals with a torque of 2.25 lb in (0.25 Nm).
10 Mounting, demounting and electric installation
10.1 Housing dimensions
①
Visual range of the display
Fig. 10-1: Housing dimensions of the built-in device VEP 15.6 in Rexroth design
24/53
VEP 15.6 Multi Touch, VEP 21.6 Multi
Destruction of screw terminals, insufficient con-
tact and loss of UL/CSA certificiation if no cop-
per wire is used and/or wrong tightening tor-
que.
1
346 mm
422 mm
38 mm
DOK-SUPPL*-VEPXX.6MTHU-IT02-EN-P
Touch