Bosch Rexroth AG
Interfaces
10
⑧
Functional earth (FE)
⑨
Male connector strip X2
Fig. 9-8: Male connector strips X2 and X3 of the keypad and functional earth connection
WARNING
The E-STOP button can be used as operating element in an E-STOP circuit
●
The E-STOP circuit has to be designed by the machine manufacturer
●
Only qualified staff may connect the E-STOP button and check it afterwards
●
It has to be connected acc. to the connection scheme
●
connection scheme" on page 23
The max. load current is 500 mA
●
9.6.1 Connections
Name at the
Connection
housing
type
X2
Keypad con-
nection
X3
Keypad con-
nection
Tab. 9-6: Keypad connections
22/53
⑩
Death or lethal injury due to incorrect handling
of the E-STOP button
Connector type (integrated)
Phönix pin contact strip,
6-pin,
SMC
G-3,81-1827318
Phönix pin contact strip,
10-pin,
SMC
G-3,81-1827350
VEP 15.6 Multi Touch, VEP 21.6 Multi
9
8
Male connector strip X3
chapter 9.6.2 "Keypad
Mating connector
Phönix socket strip,
1,5/6-
6-pin, FK-MCP 1,5/6-ST-3,81
Phönix socket strip,
1,5/10-
10-pin, FK-MCP 1,5/10-ST-3,81
DOK-SUPPL*-VEPXX.6MTHU-IT02-EN-P
Touch