KONOzw will guide you through setup. Rotate the knob to navigate through options and values. To make a
selection, press the knob once. To go back, press and hold the knob for 3 seconds. KONOzw will prompt you to
select:
Available system modes (heating, cooling, both, automatic)
Temperature unit (C/F)
System type (gas, electric, heat pump, boiler)
Temperature swing
Number of heating and cooling stages
Backlight
Factory reset
etc
Installer settings
Menu Item
Function
Number
Description
(temp digits)
01
Temperature Scale
02
User Temperature
Calibration
03
Available modes
04
Max Heat Set Temp
(skip if available modes
= cool only)
05
Min Heat Set Temp
(skip if available modes
= cool only)
06
Max Cool Set Temp
(maximum allowed cool
set temp)
07
Min Cool Set Temp
(minimum allowed cool
set temp)
08
System Type
(skip if available modes
= cool only)
09
HP valve type
Operation Guideline
D
YSTEM AND
ISPLAY
User Option Number
(time array)
F: Fahrenheit
C: Celsius
Amb Temp
+/- 5.4
00 : Heat, Cool & Auto
01 : Heat only
02 : Cool only
03 : Heat, Cool & no Auto
F: 60F – 90F
(C: 16C – 32C)
F: 45F – 75F
(C: 7C – 24C)
F: 60F – 95F
(C: 16C – 35C)
F: 50F – 75F
(C: 10C – 24C)
Furnace Gas
Furnace Electric
HP
Boiler without fan
O: O Valve
Copyright  Johnson Controls Inc 2019 All Rights Reserved
S
ETTINGS
O
F (+/-3.
0
C)
Page 14 of 19
Default setting
F
0
0
F (0
0
C)
01
90
F (32
C)
0
0
45
0
F (7
0
C)
95
0
F (35
0
C)
50
0
F (10
0
C)
Furnace Gas
O