AMX NI-2000 Programming Manual page 114

Ni series netlinx integrated controllers webconsole & programming guide
Hide thumbs Also See for NI-2000:
Table of Contents

Advertisement

Terminal (Program Port/Telnet) Commands
Terminal Commands (Cont.)
Command
SET IP <D:P:S>
SET LOG COUNT
SET QUEUE SIZE
106
Description
Sets the IP configuration of a specified device.
Enter a Host Name, Type (DHCP or Fixed), IP Address, Subnet Mask,
and Gateway IP Address.
Note: For NetLinx Central Controllers, the "Host Name" can only
consist of alphanumeric characters.
• Enter Y (yes) to approve/store the information into the Master.
• Enter N (no) to cancel the operation.
Note: The Device must be rebooted to enable new settings.
Example:
>SET IP [0:1:0]
--- Enter New Values or just hit Enter to keep current settings ---
Enter Host Name:
MLK_INSTRUCTOR
Enter IP type. Type D for DHCP or S for Static IP and then Enter:
DHCP
Enter Gateway IP:
192.168.21.2
You have entered: Host Name
Type
Gateway IP
Is this correct? Type Y or N and Enter -> y
Settings written. Device must be rebooted to enable new settings.
Sets the number of entries allowed in the message log.
Note: The Master must be rebooted to enable new settings.
Example:
>SET LOG COUNT
Current log count = 1000
Enter new log count (between 50-10000):
Once you enter a value and press the ENTER key, you get the follow-
ing message:
Setting log count to
New log count set, reboot the Master for the
change to take affect.
Provides the capability to modify maximum message queue sizes for
various threads.
Example:
set queue size
This will set the maximum message queue sizes for several threads.
Use caution when adjusting these values.
Set Queue Size Menu:
1. Interpreter (factory default=2000, currently=600)
2. Notification Manager (factory default=2000, currently=200)
3. Connection Manager (factory default=2000, currently=500)
4. Route Manager (factory default=400, currently=200)
5. Device Manager (factory default=500, currently=500)
6. Diagnostic Manager (factory default=500, currently=500)
7. TCP Transmit Threads (factory default=600, currently=200)
8. IP Connection Manager (factory default=800, currently=500)
9. Message Dispatcher (factory default=1000, currently=500)
10. Axlink Transmit (factory default=800, currently=200)
11. PhastLink Transmit (factory default=500, currently=500)
12. ICSNet Transmit (factory default=500, currently=500)
13. ICSP 232 Transmit (factory default=500, currently=500)
14. UDP Transmit (factory default=500, currently=500)
15. NI Device (factory default=500, currently=500)
Enter choice or press ESC.