2) Connection of Pipings (7K,9K BTU)
1. Remove the installation plate.
• Pull the two ' 'marked portion of bottom of the
chassis and pull the installation plate out of
chassis.
2. Route the drain hose and the indoor tubing.
For right rear piping
3. Insert the pipings, the connecting cables and
the drain pipe throught the piping hole on the
wall.
4. Connect the pipings and the indoor tubing, and
drain hose and drain pipe.
• Do not connect the cable to the indoor unit.
Pipe Size
Liquid Side (1/4")
Gas Side (3/8")
• Wrap the insulation material around the
connecting portion.
• Glue up the connection portion of drain hose and
drain pipe.
Torque
1.8kg.m
4.2kg.m
- 24 -
Installation Plate
Pull
Outdoor
Indoor
Connecting cable
Connecting piping
Drain pipe
Indoor unit tubing
Spanner
Plastic Bands
Drain Hose
Adhesive
Pull
Flare nut
Pipings
Torque wrench
Insulation material
Drain Pipe