LG LS-B0760CM/B0760HM Service Manual page 15

Table of Contents

Advertisement

5. Auto Operation
• The operation procedure is as following.
Operation mode
Indoor fan speed
Setting temperature
Intake-air
temperature
Operation Mode
If initial mode is decided, that mode is continued despite of the room temperature changing.
• Auto Operation for Cooling
Operation Condition
When Auto Operation
initial start
When Switch to Auto
Operation
Intake-Air temp.
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp. -0.5°C
(Compressor ON)
INDOOR FAN SPEED
COMPRESSOR
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
are automatically decided by Fuzzy rule.
below 21°C
Heating
Intake-air Temperature
Over 26°C
Over 24°C~below 26°C
Over 22°C~below 24°C
Over 20°C~below 22°C Intake air temperature
below 20°C
Over 20°C~below 30°C
below 20°C
over 30°C
ON
- 15 -
Over
below
~
21°C
Soft Dry
Setting Temperature
25°C
Intake air -1°C
Intake air -0.5°C
Controlled by
20°C
Fuzzy control
20°C
30°C
Fuzzy Speed
OFF
Over 24°C
24°C
Cooling
Fan Speed
Air DirectionControl
1/f rhythm
Fuzzy logic
ON
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents