9. Soft Dry Operation.
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compressor
OFF temperature is the setting temperature minus 0.5°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to the
cooling mode.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the operation
mode is switched to the Soft Dry Operation.
In this temperature range, 10min. Dry operation, 5.5min operation OFF, 1.5min. only fan operation repeat. During
10min Dry operation, even if the room temperature falls below compressor OFF temperature, 10min(MAX)
Compressor ON from starting of Dry operation which includes 4 min. Compressor ON operation below the com-
pressor OFF temperature.
• In micom dehumidify mode, control of fan speed is as following.
ROOM TEMP.
SETTING TEMP.+1
(COMP. ON)
SETTING TEMP.-0.5
(COMP. OFF)
INDOOR FAN SPEED
COMPRESSOR
10. Forced operation
• If you lose wireless remote controller, you can operate the unit with forced operation switch.
• The standard conditions are as following.
Cooling Model
Operation Mode
Cooling
Indoor Fan Speed
High
Setting Temp.
22°C
Operation
Cooling
°C
°C
1 minutes
2 minutes
Selecting
OFF
fan speed
ON
OFF
Room Temp ≥ 24°C
Cooling
High
22°C
Dry operation
10 minutes
5.5 minutes
LOW
LOW
ON
Heat pump Model
21°C ≤Room Temp
Soft Dry
Low
Room Temp.
- 19 -
1.5 minutes
maximum
10 minutes
LOW
LOW
OFF
ON
OFF
24°C
Room Temp
Heating
maximum
4 minutes
21°C
High
24°C