Adding Ethernet-Controlled Devices To The Project - AMX AXT-CA10 Instruction Manual

Design xpress-professional version 1.1
Hide thumbs Also See for AXT-CA10:
Table of Contents

Advertisement

To add the Serial device within the Device Data tab:
1. Select the type of equipment you are adding from the Source Type drop-down list.
2. Enter a name for the device in the Display Name field. This is the name for the device that will
appear on the touch panel.
3. Use the radio buttons to select Serial as the Control Method associated with the new device.
When you select a desired CD/DVD model from the Control Logic field, the changer size is
automatically filled and no longer alterable (greyed-out).
The control methods available for selection depend on the device type specified.
For example, if you select a Camera, the only control method options are Serial and
AXlink (the remaining radio buttons are both disabled).
4. Select the required baud rate for the Serial device from the Baud Rate drop-down list.

Adding Ethernet-Controlled Devices to the Project

To add a device to your system, click the Add button in the System Information dialog. This opens
the Device Configuration dialog - Device Data tab.
In the Device Data tab:
1. Select the type of equipment you are adding from the Source Type drop-down list.
2. Enter a name for the device in the Display Name field. This is the name for the device that will
appear on the touch panel.
3. Select the number of desired Output Zones.
4. Use the radio buttons to select IP as the Control Method associated with the new device.
The control methods available for selection depend on the device type specified.
For example, if you select an MP3 player, the only control method option is IP (the
remaining radio buttons are disabled).
If the option to "Warn on duplicate IP Addresses" has been selected from the Edit >
Preferences dialog, anytime you try to assign a duplicate IP Address to an Ethernet-
controllable device, you will be prompted with a pop-up dialog.
5. Select the specific device from the Control Logic drop-down list.
6. Enter the IP Address of the Ethernet-controlled device.
DXP-PRO v1.1 - Programmer's Guide
The above example uses 3 NXC-COM2 cards for communication to the external Serial
devices. If any of the other Master devices (NI-Series and ME260/64) are selected, then
there will be no need to aquire an AXB-232++ or utilize the AXlink Device IDs, as these
other Masters contain an ICSNet communication port. So to change the need to use an
AXB-232++, simply choose a Master other than the NI-700.
Good examples of Ethernet capable devices are the MAX units.