Running Patterns
To run a pattern, do the following:
1. Select the monitor where you want the pattern
to run.
2. Use the keypad to the enter the number ( 70 ,
71 , or 72 ) associated with the pattern, then
press Call Preset.
The pattern runs one time.
Repeating Patterns
To run a pattern repeatedly, do the following:
1. Select the monitor where you want the pattern
to run.
2. Use the keypad to the enter 69 , then press Call
Preset.
3. Use the keypad to enter the number (70, 71, or
72) associated with the pattern, then press Call
Preset.
The pattern repeats until a camera movement
command is issued for the dome.
Using Other Dome Features
This section describes how to flip the dome,
resume auto focus and auto iris modes, reset the
dome, adjust the v-phase, and start the dome
configuration menu.
Dome Flip
You can manually rotate the dome 180-degrees
from its current direction by entering 67 , then
pressing Call Preset.
Resuming Auto Focus / Auto Iris
The dome normally operates in auto focus and
auto iris mode. However, if you manually adjust the
focus or iris, it switches to manual focus or manual
iris mode. To resume auto focus or auto iris mode,
enter 66 , then Call Preset from the camera
controller.
DELTADOME PROGRAMMABLE SURVEILLANCE CAMERA
8000-2614-01, REV. B

Resetting the Dome

If your dome is not responding to camera
commands, it may be necessary to reset the
dome. To reset the dome, do the following:
1. Ensure that your camera controller is in
programming mode. Refer to your controller
documentation for additional information.
2. Select the number for the Dome using the
numeric keypad, then press Camera (Cam).
3. Use the numeric keypad on the camera
controller to enter 65 , then press Set Preset.
Adjusting Vertical Phase
If you experience screen rolling when you switch
cameras, you can adjust the vertical phase (V-
phase) setting of the dome. To adjust the V-phase
setting, do the following:
1. Ensure that your camera controller is in
programming mode. Refer to your controller
documentation for additional information.
2. Use the numeric keypad on the camera
controller to enter 67 , then press Set Preset.
3. To change the V-phase delay setting, use the
Iris Open and Iris Close buttons.
-Press Iris Open to increase the delay.
- Press Iris Close to decrease the delay.
4. When finished adjusting the V-phase setting,
press 67 , then Set Preset.
Start Dome Configuration Menu
Your dome provides special programming menus
to set special features for your dome. To display
these menus, do the following:
1. Ensure that your camera controller is in
programming mode. Refer to your controller
documentation for additional information.
2. Use the numeric keypad on the camera
controller to enter 66 , then press Set Preset.
Refer to the information found in the DeltaDome
Surveillance Camera Configuration Utility
Operator's Manual or Quick Reference Guide for
specific instructions on using the menus.