Operational Hopping Sequence Definition Using the Hopping Shift Parameter
Table C-6: Actual Hopping sequences, Standard Scrambling (N=6)
Hopping
Hop #1
Shift
0
910
1
914
2
918
3
912
4
920
5
916
The following formula can be used to calculate the actual hopping
sequence:
P
(i)=P
[(i+s-1)mod(N)+1]
S
0
Where:
S is the hopping shift
N=number of channels in the sequence (modulus)
P
(i) is element number i in the actual sequence with hopping shift s
S
P
(i) is element number in the basic hopping sequence (s=0).
0
For example, in the basic sequence with N=6:
P
(1) =1
0
P
(2)=3
0
P
(3)=5
0
P
(4)=2
0
P
(5)=6
0
P
(6)=4
0
For a shift of 3, the actual sequence is:
P
(1) =P
[(1+3-1)mod6+1]=P
3
0
P
(2) =P
[(2+3-1)mod6+1]=P
3
0
P
(3) =P
[(3+3-1)mod6+1]=P
3
0
Manual Revision 1.0
Hop #2
Hop #3
914
918
918
912
912
920
920
916
916
910
910
914
(4)=2
0
(5)=6
0
(6)=4
0
Hop #4
Hop #5
912
920
920
916
916
910
910
914
914
918
918
912
Hop #6
916
910
914
918
912
920
C-13