External Trigger To Switch Fire Detection Mode - Bosch AVIOTEC IP starlight 8000 Planning Manual

Hide thumbs Also See for AVIOTEC IP starlight 8000:
Table of Contents

Advertisement

38
en | Use cases
2.
Link any number of 15-minute intervals with the VCA profiles for each day of the week. Moving
the mouse cursor over the table displays the time below it. This aids orientation.
1.
2.
3.
4.
5.
6.
Define holidays on which a profile should be active that are different to the standard weekly
schedule.
1.
2.
3.
4.
5.
Deleting Holidays
Delete defined holidays at any time:
1.
2.
3.
4.
Notice!
If you have not yet created any fire detection profiles (see Fire detection and VCA profiles,
page 37 ), you must do so and go to Configuration > Alarm > Fire detection.
Refer to
6.4

External trigger to switch fire detection mode

This configuration allows you to change the VCA profile / fire detection profile when triggered
by an event.
4
The camera offers two alarm inputs (see chapter Alarm input).
1.
2.
3.
4.
2020.08 | 1.0 | F.01U.391.016
In the VCA configuration drop-down list, select Scheduled.
Click the profile to link in the Time periods field.
Click in a field in the table, hold down the mouse button and drag the cursor over all the
periods to be assigned to the selected profile.
Use the right mouse button to deselect any of the intervals.
Click Select All to link all time intervals to the selected profile.
Click Clear All to deselect all of the intervals.
When finished, click Set to save the settings in the device.
Click the Holidays tab. Any days that have already been selected are shown in the table.
Click Add. A new window opens.
Select the desired date from the calendar. Select several consecutive calendar days by
holding down the mouse button. These will later be displayed as a single entry in the
table.
Click OK to accept the selection. The window closes.
Assign the individual holidays to the VCA profiles, as described above.
Click Delete. A new window opens.
Click the date to delete.
Click OK. The item is deleted from the table and the window closes.
The process must be repeated for deleting additional days.
Fire detection and VCA profiles, page 37
In the VCA configuration drop-down list, select Event triggered.
In Configuration select Trigger.
Select a physical alarm (alarm input) as a trigger, choose Alarm input 1 or Alarm input 2.
In Trigger active select the VCA configuration that is to be enabled via an active trigger.
A green check mark to the right of the list field indicates that the trigger is active.
In Trigger inactive select the VCA configuration that is to be activated if the trigger is not
active.
A green check mark to the right of the list field indicates that the trigger is inactive.
Planning manual
AVIOTEC IP starlight 8000
Bosch Sicherheitssysteme GmbH

Advertisement