Bosch AVIOTEC IP starlight 8000 Planning Manual page 39

Hide thumbs Also See for AVIOTEC IP starlight 8000:
Table of Contents

Advertisement

AVIOTEC IP starlight 8000
Delay [s]
Select the delay period for the reaction of the video content analysis to trigger signals. The
alarm is only triggered after a set time interval in seconds has elapsed and then only if the
triggering condition still exists. If the original condition has been restored before this time
interval elapses, the alarm is not triggered. A delay period may be useful in avoiding false
alarms or frequent triggering. During the delay period, the Silent VCA configuration is always
enabled.
4
Notice!
If you have not yet created any fire detection profiles (see Fire detection and VCA profiles,
page 37 ), you must do so and go to Configuration > Alarm > Fire detection.
One example would be an environment with cleaning cycles. A key switch can be used as an
external trigger to switch between the different fire detection profiles.
Bosch Sicherheitssysteme GmbH
Go to Interfaces, select Alarm Inputs and adapt the corresponding alarm input to your
needs.
Planning manual
Use cases | en
39
2020.08 | 1.0 | F.01U.391.016

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcs‑8000‑vfd‑b

Table of Contents