Bosch AVIOTEC IP starlight 8000 Operation And Commissioning Manual

Bosch AVIOTEC IP starlight 8000 Operation And Commissioning Manual

Hide thumbs Also See for AVIOTEC IP starlight 8000:
Table of Contents

Advertisement

Quick Links

AVIOTEC IP starlight 8000
FCS‑8000‑VFD‑B / Firmware 7.7x
en
Operation and Commissioning Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch AVIOTEC IP starlight 8000

  • Page 1 AVIOTEC IP starlight 8000 FCS‑8000‑VFD‑B / Firmware 7.7x Operation and Commissioning Manual...
  • Page 3: Table Of Contents

    AVIOTEC IP starlight 8000 Table of contents | en Table of contents Safety instructions General Safety Messages / Notices Introduction Disclaimer About this manual Conventions in this manual Definition of optical terms 2.4.1 Illumination 2.4.2 Focal length 2.4.3 Monitoring Area 2.4.4...
  • Page 4 | Table of contents AVIOTEC IP starlight 8000 9.1.1 Quick solution to solve false alarms 9.1.2 False alarms under 4 seconds concerning the whole detection area 9.1.3 False alarms at small constant areas 9.1.4 Vibrations at the camera site...
  • Page 5: Safety Instructions

    AVIOTEC IP starlight 8000 Safety instructions | en Safety instructions In this document, the following symbols and notations are used to draw attention to special situations: Danger! Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 6 | Safety instructions AVIOTEC IP starlight 8000 Caution! Make sure to test the fire detection after updating to the latest firmware. Notice! Avoid obstructions in the field of view! Covered fires cannot be detected correctly. An unobstructed view of the detection area is necessary.
  • Page 7 AVIOTEC IP starlight 8000 Safety instructions | en Notice! Avoid backlight. Backlight can disturb the video-based fire detection algorithm. Notice! Optimized smoke detection. The video-based fire detection algorithm is optimized for smoke of smoldering fires. Notice! Qualified personnel only. Assembly and installation must only be performed by qualified personnel.
  • Page 8: Introduction

    For more information please contact the nearest Bosch Security Systems location or visit www.boschsecurity.com . All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
  • Page 9: Focal Length

    AVIOTEC IP starlight 8000 Introduction | en Illumination is an important influencing factor for sensible optical systems. Natural light shows the huge range of illumination values from direct sunlight (~100.000 lx) to full moon on a clear night (~1.0 lx). A luxmeter can be used to measure the light levels.
  • Page 10: Monitoring Area

    | Introduction AVIOTEC IP starlight 8000 The maximum distance to a detectable fire may be reached by adjusting the largest focal length which decreases the width of the field of view to the minimum (green). 2.4.3 Monitoring Area The monitoring area defines the effective space that can be observed by the video-based fire detection.
  • Page 11 AVIOTEC IP starlight 8000 Introduction | en Opening angle of the lens The opening angle of the lens can be set from wide-angle to telephoto setting. This influences the field of view of the camera. Angle for vertical alignment of the camera The vertical alignment of the camera is also important for the video-based fire detection.
  • Page 12 | Introduction AVIOTEC IP starlight 8000 Angle for horizontal alignment of the camera Align the camera according to your application by adjusting the angle of the horizontal alignment of the camera. 2020.08 | 01 | F.01U.391.015 Operation and Commissioning Manual...
  • Page 13: System Overview

    The video-based fire detection is the system of choice when reliable video motion and fire detection is needed, e.g. applications which are not subjected to construction product regulation or a supplementation to existing fire detection systems. AVIOTEC IP starlight 8000 operates as stand-alone unit and doesn’t need a separate evaluation unit. Furthermore, it contains all features of the Intelligent Video Analytics which allows analyzing and evaluating moving objects in parallel.
  • Page 14 | System Overview AVIOTEC IP starlight 8000 The video-based fire detection is optimized for smoke of smoldering fires. The algorithm analyzes smoke based on physical characteristics. Typically a plume of smoke is formed in a regular upward motion of smoke at the same position. This is characterized by a thick column of smoke which is directly visible.
  • Page 15 AVIOTEC IP starlight 8000 System Overview | en Smoke plumes must move in a constant direction with a minimum density to be detected by the video-based fire detection. Irregular expanding smoke and smoke plumes moving in the direction of the camera might not be detected.
  • Page 16 | System Overview AVIOTEC IP starlight 8000 σ σ Figure 3.1: Smoke density definition The effect of contrast reduction by smoke is described by the formula with the contrast values for a temporal average image with smoke σ and the contrast for the background σ...
  • Page 17 AVIOTEC IP starlight 8000 System Overview | en Smoke density: 40% Smoke density: 90% In regular conditions with an equal colored background, smoke is visible when the smoke density exceeds 40%. In case of a background with high color saturation (e.g. deep blue) or a high background intensity or strong contrasts or very strong color contrast (e.g.
  • Page 18: Installation

    | Installation AVIOTEC IP starlight 8000 Installation Notice! Do not expose the image sensors to direct sunlight. Do not obstruct the free flow of air around the camera. Notice! Avoid backlight. Backlight can disturb the video-based fire detection algorithm.
  • Page 19: Preparation In The Office

    AVIOTEC IP starlight 8000 Installation | en Preparation in the office We recommend that you prepare the installation in the office, as you can carry out many tasks here that are not recommended under time pressure and possibly on lifting platforms etc.
  • Page 20: Camera Mounting

    | Installation AVIOTEC IP starlight 8000 Remove the sensor protection cap from the camera. Remove the protection cap from the lens. Screw the lens onto the camera. Plug the lens connector into the camera (it automatically detects the type of lens).
  • Page 21: Setting The Field Of View

    AVIOTEC IP starlight 8000 Installation | en Ceiling mount Wall mount Stand mount Chose the right mounting variant for your application and mount the device according to the following options: Install the mounting bracket. Attach the camera to the bracket and tighten the camera lock ring.
  • Page 22: Wiring Of The Camera

    | Installation AVIOTEC IP starlight 8000 Wiring of the camera Connection to Ethernet via PoE Ethernet cable Notice! Use only PoE approved devices. The camera is intended to be powered via a STP Category 5e cable in a Power-over-Ethernet (PoE) network environment .
  • Page 23: Alarm Output

    AVIOTEC IP starlight 8000 Installation | en Auxilliary 12 V DC power supply Caution! Use only a +12 VDC power supply as an auxiliary power source. The auxiliary power supply unit must be isolated from earth. Caution! The Low Voltage power supply unit must comply with EN/UL 60950. The power supply must be a SELV-LPS unit or a SELV - Class 2 unit (Safety Extra Low Voltage - Limited Power Source).
  • Page 24: Alarm Input

    | Installation AVIOTEC IP starlight 8000 Alarm out Use the alarm output for switching external devices such as lamps or sirens. Alarm output switching capability: – Max. voltage 30 VAC or +40 VDC. Max. 0.5 A continuous, 10 VA. Alarm socket Alarm out The maximum wire diameter is 18-28 AWG, UL 16-28 AWG for both stranded and solid;...
  • Page 25 AVIOTEC IP starlight 8000 Installation | en 4 5 6 4 5 6 1 2 3 1 2 3 7 mm (0.28 in) MENU CVBS Alarm 4 5 6 ≤2 mm 1 2 3 (0.08 in) Alarm in: Use the alarm input to connect external alarm devices such as door contacts or sensors: –...
  • Page 26 | Installation AVIOTEC IP starlight 8000 Alarm socket Ground The maximum wire diameter is 18-28 AWG, UL 16-28 AWG for both stranded and solid; cut back 7 mm (0.28 in) of insulation. 2020.08 | 01 | F.01U.391.015 Operation and Commissioning Manual Bosch Sicherheitssysteme GmbH...
  • Page 27: Camera Integration

    AVIOTEC IP starlight 8000 Camera integration | en Camera integration The video-based fire detection can be easily integrated into the network environment of the customer. There are several possibilities to connect the camera. Various combinations are possible. The individual customer network properties determine the performance and scalability of the system.
  • Page 28: Local Area Network

    | Camera integration AVIOTEC IP starlight 8000 Mobile devices Local Area Network Due to the IP-based camera, the integration of the video-based fire detection into the network of the customer is easy. There are a lot of opportunities regarding to scalability and enlargement of the network.
  • Page 29: Monitoring Center

    In a monitoring center, alarms can be verified to call the fire brigade and to take care of additional rescue measures. Fire Alarm Control Panel AVIOTEC IP starlight 8000 can be connected to the a fire alarm control panel. The alarm will be triggered by the relay output of the camera. Notice! No direct connection to fire services in EN54 compliant installations.
  • Page 30 | Camera integration AVIOTEC IP starlight 8000 Connection to a fire alarm control panel The alarm output of the camera can be connected to a fire alarm control panel. The camera alarm output is triggered by a relay that is normally open. In case of alarm the relay is closed.
  • Page 31: Mobile Devices

    AVIOTEC IP starlight 8000 Camera integration | en Mobile Devices Another advantage of the network integration of the video-based fire detection is the expandability to mobile devices, such as tablets or smartphones. Bosch Sicherheitssysteme GmbH Operation and Commissioning Manual 2020.08 | 01 | F.01U.391.015...
  • Page 32: Access To The Device

    | Access to the device AVIOTEC IP starlight 8000 Access to the device The unit must have a valid IP address and a compatible subnet mask to operate on your network. If the network has a DHCP server for the dynamic assignment of IP addresses, select On or On plus Link-Local to automatically accept the DHCP-assigned IP address.
  • Page 33: Adjustment Of Detection Settings

    AVIOTEC IP starlight 8000 Adjustment of detection settings | en Adjustment of detection settings The standard settings of the video-based fire detection will be sufficient for the most customer environments. Nevertheless, there are many ways to adapt the flame and smoke detection to the requirements of the customer.
  • Page 34: Adjustments Of Image Regions

    | Adjustment of detection settings AVIOTEC IP starlight 8000 Verification time [s] of the smoke detection can be set from 10 to 30 seconds. The default value is 15 seconds. Small values cause faster detection (higher risk of false alarms), larger values decrease false alarms.
  • Page 35 AVIOTEC IP starlight 8000 Adjustment of detection settings | en Masking Due to the different areas of application of the camera, false alarms may be the result in individual customer environments. Algorithm disturbing elements which have an appearance similar to flames and smoke, for example ascending steam of a machine, must be excluded from the detection area.
  • Page 36 | Adjustment of detection settings AVIOTEC IP starlight 8000 for each mask: 5 ... 120. A clock icon with a small smoke plume is displayed at the bottom right-hand corner. Verification time flames The following settings (in seconds) are possible to assign an individual verification time for each mask: 4 / 8 / 12 / 16.
  • Page 37: Adaptation To The Lighting Situation

    AVIOTEC IP starlight 8000 Adjustment of detection settings | en Delete Automasks Notice! Delete automasks if you changed the camera position, zoom, point of view or after a fire. Also delete automasks if the spatial arrangement of objects in the detection area has changed fundamentally.
  • Page 38 | Adjustment of detection settings AVIOTEC IP starlight 8000 The camera includes a built-in relay that switches in case of a flame or a smoke alarm. The relay is switched during the alarm and returns to its initial state after the alarm.
  • Page 39: Use Cases

    AVIOTEC IP starlight 8000 Use cases | en Use cases Fire detection in combination with VCA functionality offers different use cases. These four use cases are described below. Fire detection only This is the standard setting of the camera. You can choose this standard option if different fire detection profiles and profile scheduling are not necessary for your application.
  • Page 40: External Trigger To Switch Fire Detection Mode

    | Use cases AVIOTEC IP starlight 8000 In the VCA configuration drop-down list, select Scheduled. Link any number of 15-minute intervals with the VCA profiles for each day of the week. Moving the mouse cursor over the table displays the time below it. This aids orientation.
  • Page 41 AVIOTEC IP starlight 8000 Use cases | en Delay [s] Select the delay period for the reaction of the video content analysis to trigger signals. The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists.
  • Page 42: Troubleshooting

    | Troubleshooting AVIOTEC IP starlight 8000 Troubleshooting The following issues can be solved in the detection settings (Configuration > Alarm > Fire detection). False Alarms 9.1.1 Quick solution to solve false alarms A fast way to identify and solve region-stable false alarms in the camera image is automasking.
  • Page 43: Vibrations At The Camera Site

    AVIOTEC IP starlight 8000 Troubleshooting | en 9.1.4 Vibrations at the camera site Problem Solution Vibrations are transferred to the camera. Avoid vibrations at the camera site. Camera picture is trembling. Make sure the camera is firmly mounted. The camera position changed because of Move the camera to its initial position and vibrations.
  • Page 44 | Troubleshooting AVIOTEC IP starlight 8000 In the address bar of your browser, after the unit IP address, enter: /version for example: 192.168.0.80/version Write down the information or print out the page. The camera offers a variety of configuration options. Therefore, check that it works properly after installation and configuration.
  • Page 45: Maintenance

    AVIOTEC IP starlight 8000 Maintenance | en Maintenance 10.1 Cleaning It is generally sufficient to use a dry cloth for cleaning, but a moist lint-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol cleaners.
  • Page 46 | Maintenance AVIOTEC IP starlight 8000 Testing Inspection frequency Item to inspect annually quarterly regularly Check the camera lens for pollution and damage Functional check Check of the video image 2020.08 | 01 | F.01U.391.015 Operation and Commissioning Manual...
  • Page 47: Technical Data

    AVIOTEC IP starlight 8000 Technical data | en Technical data Algorithm Overview Min. detection size for Smoke, standard setting (% of picture width) Smoke speed 0.7 - 8.4 (% of picture height /s) Min. Smoke density (%) Min. detection size for Flame, standard setting (% of picture width) Min.
  • Page 48 | Technical data AVIOTEC IP starlight 8000 Local storage Recording Continuous recording, ring recording. alarm/events/schedule recording Mechanical Dimensions (W x H x L) 78 x 66 x140 mm (3.07 x 2.6 x 5.52 inch) without lens Weight 855 g (1.88 lb) without lens Color RAL 9006 Metallic Titanium Tripod Mount Bottom and top 1/4-inch 20 UNC...
  • Page 49: Appendices

    AVIOTEC IP starlight 8000 Appendices | en Appendices Maximum detection distances for margin areas Due to the optical distorsion of the lens, there are deviating maximum detection distances at the margin area of the picture. Figure 12.1: Definition of margin areas of the picture...
  • Page 50 | Appendices AVIOTEC IP starlight 8000 0.75 39.8 27.3 22.1 45.7 53.1 36.5 29.5 60.9 1.25 66.4 45.6 37.0 76.2 79.7 54.7 44.3 91.4 106.3 73.0 59.2 121.9 132.9 91.3 74.0 152.4 159.5 109.6 88.8 182.9 Opening angle 90°...
  • Page 51: Smoke Detection

    AVIOTEC IP starlight 8000 Appendices | en 0.75 65.4 58.6 54.9 69.1 87.3 78.2 73.3 92.2 1.25 109.1 97.7 91.6 115.2 131.0 117.3 110.0 138.3 174.7 156.4 146.7 184.4 218.3 195.5 183.4 230.5 262.0 234.6 220.1 276.6 Opening angle 45°...
  • Page 52 | Appendices AVIOTEC IP starlight 8000 20.5 15.4 13.7 23.0 0.75 30.8 23.1 20.6 34.5 41.1 30.8 27.5 46.0 1.25 51.3 38.5 34.4 57.5 61.6 46.2 41.3 69.0 82.3 61.7 55.1 92.1 102.8 77.1 68.9 115.1 123.4 92.6 82.7 138.1...
  • Page 53: Lvf-8008C-P0413

    AVIOTEC IP starlight 8000 Appendices | en 40.8 38.3 37.5 42.0 0.75 61.3 57.5 56.3 63.0 81.7 76.7 40.7 84.0 1.25 102.1 95.9 50.9 105.0 122.6 115.1 112.6 126.0 163.5 153.5 150.2 168.1 204.4 191.9 187.8 210.1 245.3 230.3 225.3 252.1...
  • Page 54 | Appendices AVIOTEC IP starlight 8000 Opening angle 60° Fire width (m) 26.3 23.4 21.8 27.6 43.9 39.1 36.4 46.0 0.75 65.9 58.7 54.7 69.1 87.9 78.2 73.0 92.1 1.25 109.9 97.9 91.3 115.2 131.9 117.4 109.5 138.2 175.9 156.6...
  • Page 55: Smoke Detection

    AVIOTEC IP starlight 8000 Appendices | en 12.2.2 Smoke detection Opening angle 100° Fire width (m) 10.9 12.9 18.2 12.4 21.5 0.75 27.4 18.6 14.5 32.3 36.6 24.9 19.4 43.1 1.25 45.7 31.0 24.2 53.8 54.9 37.3 29.1 64.6 73.2 49.8...
  • Page 56: Lvf-5005N-S1250

    | Appendices AVIOTEC IP starlight 8000 Opening angle 45° Fire width (m) 24.4 22.7 22.1 25.3 40.8 37.9 36.9 42.2 0.75 61.2 56.8 55.4 63.3 81.8 75.9 73.9 84.5 1.25 102.2 94.8 92.4 105.6 122.6 113.8 110.9 126.7 163.6 151.8...
  • Page 57 AVIOTEC IP starlight 8000 Appendices | en 397.7 381.9 374.9 404.6 477.2 458.3 449.8 485.5 Opening angle 26° Fire width (m) 60.5 59.0 58.4 61.2 100.8 98.3 97.3 102.0 0.75 151.2 147.5 146.0 153.0 201.6 196.6 194.7 204.0 1.25 252.0 245.8...
  • Page 58: Smoke Detection

    | Appendices AVIOTEC IP starlight 8000 935.0 929.9 925.1 938.4 1122.1 1115.9 1110.2 1126.1 Opening angle 8.5° Fire width (m) 184.9 184.4 184.1 185.1 308.1 307.4 306.9 308.5 0.75 462.2 461.1 460.4 462.8 616.2 614.8 613.8 617.0 1.25 770.3 768.5...
  • Page 59 AVIOTEC IP starlight 8000 Appendices | en 282.3 275.3 272.6 285.6 352.9 344.1 340.7 357.0 423.5 413.0 408.9 428.4 Opening angle 20° Fire width (m) 54.9 54.1 53.7 55.3 91.6 90.4 89.7 92.3 0.75 137.4 135.5 134.5 138.4 183.3 180.8 179.5...
  • Page 60: Commissioning Report

    | Appendices AVIOTEC IP starlight 8000 862.8 860.8 859.5 863.9 1078.5 1076.0 1074.4 1079.9 1294.1 1291.2 1289.2 1295.8 12.4 Commissioning report Camera installation and configuration protocol General Camera name (Configuration -> General - > Identification) Firmware version (Configuration -> Service -> System Overview) Date/Time setting o Synchronized (Configuration -> General -> Date/Time)
  • Page 61 AVIOTEC IP starlight 8000 Appendices | en Lens settings Lens opening angle ALC mode (Configuration -> Camera -> Installer Menu -> ALC mode) Focus Position Day mode Night mode (Configuration -> Camera -> Installer Menu -> Lens Wizard... -> Focus position) Focus Indicator Day mode Night mode (Configuration -> Camera -> Installer Menu -> Lens Wizard... -> Focus indicator) IR-corrected lens o On     o Off (Configuration -> Camera -> Installer...
  • Page 62 | Appendices AVIOTEC IP starlight 8000 Privacy Masks o Yes     o No (Please add a screenshot) 2020.08 | 01 | F.01U.391.015 Operation and Commissioning Manual Bosch Sicherheitssysteme GmbH...
  • Page 63 AVIOTEC IP starlight 8000 Appendices | en Further configuration (e.g. recording, DynDNS, VCA configuration, Alarm Inputs …): Bosch Sicherheitssysteme GmbH Operation and Commissioning Manual 2020.08 | 01 | F.01U.391.015...
  • Page 64 | Appendices AVIOTEC IP starlight 8000 Installation conditions / application Scene illumination Check the minimum illuminance is ≥ 2 lx o Yes     o No    Min. Illuminance:                    lx Check if illumination in B/W mode with IR- o Yes     o No illuminators is sufficient Check if Day/Night setting is correct o Yes     o No...
  • Page 65 AVIOTEC IP starlight 8000 Appendices | en Smoke test results (smoke cartridges) Day/Night Color Monochrome Distance to smoke cartridge Illumination Smoke cartridge(s) Smoke detected o Yes     o No o Yes     o No Field of view (Please add a screenshot) Smoke test results (test video) Day/Night Color...
  • Page 66 | Appendices AVIOTEC IP starlight 8000 Flame test results (test video) Day/Night Color Monochrome Distance to monitor Illumination Flame detected o Yes     o No o Yes     o No Field of view (Please add a screenshot) Smoke/flame test results (test video) Day/Night Color Monochrome Distance to monitor...
  • Page 67 AVIOTEC IP starlight 8000 Appendices | en Place: Issuer: Date: Signature: Bosch Sicherheitssysteme GmbH Operation and Commissioning Manual 2020.08 | 01 | F.01U.391.015...
  • Page 68 | Appendices AVIOTEC IP starlight 8000 2020.08 | 01 | F.01U.391.015 Operation and Commissioning Manual Bosch Sicherheitssysteme GmbH...
  • Page 70 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2020 202009011112...

This manual is also suitable for:

Fcs‑8000‑vfd‑b01u.317.536