Table 4-8
Technical specifications for Basic Line Modules (500 V – 690 V 3 AC)
Order number
kVA rating
1)
Max. infeed power
Rated DC link current
Base load DC link current
Maximum DC link current
Input current for 690 V 3 AC
Max. input current for 690 V 3 AC
Line supply voltages:
- Line voltage
- Line frequency
- Electronics power supply
DC link voltage
Electronics current drain (24 V DC)
Cooling type
DC link capacitance
Charging limit
Power loss
- Air / Coolant
- Total losses
Max. coolant temperature:
- without derating
- with derating
Coolant requirement
3)
Liquid volume of integrated heat exchanger
Typ. pressure drop with volumetric flow
Sound pressure level
Line/power connection
Max. connection cross-section
Line connection (U1, V1, W1)
DC link connection (DCP, DCN)
PE connection
Degree of protection
Dimensions
Width
Height
Depth
Frame size
Weight
UL listed fuse
5)
Number (connected in parallel)
Rated current
Size acc. to DIN 43620-1
kVA rating refers to the rated motor power of a typical 6-pole motor supplied with 690 V.
1)
Valid for a 60 s duty cycle (overload period) and a duty cycle duration of 300 s based on the base load
2)
DC link current.
This value applies to both coolant options, i.e. water and water / Antifrogen N mixture with 45 %
3)
Antifrogen N.
This value applies to the water coolant option; for other coolant types, see Chapter 8.
4)
In order to build a UL-approved system, it is absolutely essential to use the specified fuses.
5)
Chassis Power Units Liquid Cooled
SINAMICS S120 Equipment Manual, Edition 04/2007, 6SL3097-2AM00-0BP2
6SL3335–
kW (Pn)
kW
(Pmax)
A
A
A
2)
A
A
V
Aceff
Hz
V
DC
V
DC
A
µF
µF
kW
kW
°C
°C
l/min
dm³
Pa
4)
dB(A)
mm²
mm²
mm²
mm
mm
mm
kg
1TG34-2AA0
1TG37-3AA0
355
630
533
945
420
730
328
570
630
1095
340
600
510
900
500 3 AC –10 % to 690 3 AC +10 % (-15 % < 1 min)
24 (20.4 – 28.8)
0.7
0.7
Liquid cooling with integrated aluminium heat exchanger
4800
7700
38400
61600
0.21 / 1.55
0.38 / 2.71
1.76
3.09
45
45
50
50
9
9
0.45
0.45
70000
70000
54
54
Flange connection with screws M12
4 x 240
4 x 240
Busbar
Busbar
2 x 240
2 x 240
IP00
IP00
160
160
1153
1153
545
545
FBL
FBL
108
108
3NE1 333-2
3NE1 331-2
1
2
450
350
2
2
Line Modules
4.2 Basic Line Modules
1TG41–3AA0
1TG41–7AA0
1100
1370
1650
2055
1300
1650
1014
1287
1950
2475
1070
1350
1605
2025
47 to 63 Hz
1.35 x U
line
0.7
0.7
15500
19300
124000
154400
0.43 / 4.66
0.55 / 5.70
5.09
6.25
45
45
50
50
12
12
0.79
0.79
70000
70000
56
56
4 x 240
4 x 240
Busbar
Busbar
2 x 240
2 x 240
IP00
IP00
160
160
1508
1508
545
545
GBL
GBL
185
185
3NE1 447-2
3NE1 435-2
2
3
670
560
3
3
4-15