Siemens SINAMICS S120 Equipment Manual page 107

Chassis power units liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 6-14
Technical specifications for dv/dt filter with Voltage Peak Limiter, 500 V – 690 V 3 AC
Order number:
Suitable for Motor Module
Rated output of the Motor
Module
dv/dt reactor
I
thmax
Power loss, typical
Connections
- to Motor Module
- Load
- PE
Max. permissible cable
length between dv/dt
reactor and motor
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
Voltage limiting network (Voltage Peak Limiter)
I
thmax
Power loss
Connections
- to dv/dt reactor
- DC
- PE
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
Note
For versions with 2 dv/dt reactors, the cable lengths specified in the table must not be
doubled.
Two dv/dt reactors are required for these Motor Modules. The technical specifications provided apply to one
1
dv/dt reactor.
Chassis Power Units Liquid Cooled
SINAMICS S120 Equipment Manual, Edition 04/2007, 6SL3097-2AM00-0BP2
6SL3000-
2DH35-8AA0
6SL3325-
1TG35-8AA0
kW
560
A
575
kW
0.72
M12
M12
M6
m
IP00
mm
460
mm
385
mm
312
kg
172
A
575
kW
0.063
M8
M8
M8
IP00
mm
309
mm
1312.5
mm
400
kg
48
Motor-Side Power Components
6.3 dv/dt filter with Voltage Peak Limiter
2DH38-1AA0
2DH41-3AA0
1TG38-1AA0
1TG41-0AA0
1
800
810
0.693
0.715
M12
M12
M6
300 (shielded)
450 (non-shielded)
IP00
445
385
312
160
810
0.106
M10
M10
M8
IP00
309
1312.5
1312.5
400
72
2DH41-3AA0
1TG41-3AA0
1
1000
1200
1270
1270
0.715
M12
M12
M12
M12
M6
M6
IP00
IP00
445
445
385
385
312
312
164
164
1270
1270
0.15
0.15
M10
M10
M10
M10
M8
M8
IP00
IP00
309
309
1312.5
400
400
72
72
1
6-21

Advertisement

Table of Contents
loading

Table of Contents