1.3
Technical specifications
Technical specifications
Unless explicitly specified otherwise, the following technical specifications are valid for all the
following components of the SINAMICS S120 Liquid Cooled drive system.
Table 1-1
General technical specifications
Electrical data
Line connection voltage
Line frequency
Output voltage
Output frequency
Electronic power supply
Short-circuit current rating SCCR in accordance
with UL508C (up to 600 V)
Radio interference suppression
Overvoltage category
Mechanical data
Vibratory load
Transportation
•
1
Operation
•
Shock stressing
Transportation
•
1
Operation
•
Environmental requirements
Degree of protection
Protection Class
Cooling method
Cooling circuit (refer to Chapter 8)
Max. system pressure with respect to
•
atmosphere
Pressure drop at rated volumetric flow
•
Recommended pressure range
•
Inlet temperature of liquid coolant
•
in packaging for transportation
1
Chassis Power Units Liquid Cooled
SINAMICS S120 Equipment Manual, Edition 04/2007, 6SL3097-2AM00-0BP2
380 V 3 AC –10 % to 490 V 3 AC +10 % (-15 % < 1 min)
500 V 3 AC –10 % to 690 V 3 AC +10 % (-15 % < 1 min)
47 Hz to 63 Hz
0 to line connection voltage (depending on the infeed type)
0 Hz to 300 Hz
24 VDC (20.4 V - 28.8 V)
1.1 kW - 298 kW:
•
299 kW - 447 kW:
•
448 kW - 671 kW:
•
672 kW - 1193 kW:
•
>1194 kW:
•
Category C3 (environment 2) to EN 61800-3
Class III to EN 60664-1
EN 60721-3-2, class 2M2
•
Test values in accordance with EN 60068-2-6 test Fc:
•
10 to 58 Hz with constant deflection = 0.075 mm
–
58 to 200 Hz with constant acceleration = 9.81 m/s² (1 g)
–
EN 60721-3-2, class 2M2
•
Test values in accordance with EN 60068-2-27 test Ea:
•
98 m/s² (10 g) / 20 ms
IP00 acc. to EN 60529
Class I (with protective conductor system) and class III (PELV) to
EN 61800-5-1
Liquid cooling
600 kPa
•
70 kPa
•
80 kPa to 200 kPa
•
Dependent on ambient temperature, no condensation permitted
•
0°C to + 45 °C without derating, >45 °C to + 50 °C see derating
–
characteristics
(antifreeze essential for temperature range between 0 °C and
–
5 °C; recommended antifreeze agent: "Antifrogen N" supplied by
Clariant)
1.3 Technical specifications
42 kA
65 kA
84 kA
170 kA
200 kA
System Overview