8.13. RECEIVE DIAGNOSTIC RESULTS Command (1Ch)

8.13.1. Supported Diagnostics Page (00h)

Address. The Tape Drive in the autoloader supports only LUN=0, therefore this
is always 0.
When the S/N bit is 1, the Tape Drive Serial Number field is the drive serial
number (10 bytes).
Other fields are the same as described in section 8.12.3.
The RECEIVE DIAGNOSTIC RESULTS command returns the analysis from
the host after a SEND DIAGNOSTIC command.
Bit
7
6
Byte
0
1
Logical unit number(0h)
2
3
(MSB)
4
5
Table 8.13.1 : RECEIVE DIAGNOSTIC RESULTS command
The Allocation Length specifies the number of bytes of Diagnostic Data that can
be received.
The Supported Diagnostic Page lists all Diagnostic Page Codes implemented by
the autoloader starting from 00h, in number order.
Bit
7
6
Byte
0
1
2
(MSB)
3
4
5
6
7
Table 8.13.1.1 : Supported Diagnostic Page (00h)
The Page Code indicates that this page is a Supported Diagnostic Page.
The Page Code Length indicates the number of following bytes transmitted in
this page.
5
4
3
2
Operation code (1Ch)
Reserved
Reserved
Allocation length
Control(0h)
5
4
3
2
Page Code(00h)
Reserved
Page Length(0004h)
Supported Diagnostics(00h)
Home Position(80h)
Cycle pick/place cartridge(81h)
Cycle elevator axis(82h)
Chapter 8 SCSI Commands
1
0
(LSB)
1
0
(LSB)
113