Figure 2-3 Mdu Cabling - Alcatel-Lucent 7330 Product Information Manual

Intelligent services access manager
Hide thumbs Also See for 7330:
Table of Contents

Advertisement

Indoor ONT
Riser
ONT
PC
TV
PC
TV
PC
TV
Fiber
patch
panel
MDU installation planning considerations include:
number of units served
cable and conduit accessibility
ownership of cable
customer take-up rate
Other planning considerations:
Running cable in older buildings can be more complicated.
Running fiber to each unit in an MDU can be a better option when the existing
cable is not owned by the service provider.
When there is no access to the existing cable in an MDU, you can use existing
coaxial or Cat5e, or better wiring.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
3FE 54199 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview

Figure 2-3 MDU cabling

Fiber cabling
PC
TV
PC
TV
PC
TV
PC
TV
Note 1 —
Ensure that Cat5e or higher wiring is used.
Note 2 —
Alcatel-Lucent recommends that in the fiber distribution
network, APC-based or spliced connections, are used to avoid
potential problems. In particular, splitters should be configured so that
unused ports are terminated on APC-based connectors.
Edition 01 ONT Product Information Guide
VDSL
Riser
modem
PC
TV
PC
TV
PC
TV
MDU
ONT
Drop terminal
March 2011
MDU ONT
Coax, CAT
PC
TV
PC
TV
PC
TV
PC
TV
19440
2-19

Hide quick links: