Siemens SIRIUS 3RA6 System Manual page 94

Compact starter
Hide thumbs Also See for SIRIUS 3RA6:
Table of Contents

Advertisement

3RA64/3RA65 compact starter with IO-Link
6.2 Description of the hardware
No.
Display element/operator control
(4)
"Overload trip class" selector
switch
(5)
"Overload protection function" test
button
(6)
Actuator
(7)
Connection point for auxiliary
switch block
(8)
Control circuit terminal
(9)
Main circuit terminals
(10)
"Device status" LED display
(11)
"Main contacts closed" LED display STATE ON I
(12)
"Group error" LED display
(13)
"Short-circuit protection function"
test button
(14)
"Malfunction" mechanical display
(15)
Warning notice
(16)
Interface for connecting cable
(input)
(17)
Interface for connecting cable
(output)
You can find information on the device statuses in " Diagnostics (Page 118)".
1)
You can find information on the terminal block pin assignments in "Connecting the
2)
3RA64/3RA65 compact starter with IO-Link (Page 127)".
You can find information on the external auxiliary switch block in "External auxiliary switch
3)
block (Page 150)".
Reference to "Parameter "Operation at Preset <> Actual Configuration" (Page 108)".
4)
94
Marking
Description
CLASS 10/20
For selecting the overload trip class 10E or 20E.
TEST
Press this button for at least 5 secs to test the overload
protection function.
OFF
READY
TRIPPED
TRIPPED: Short circuit or malfunction.
You can plug an auxiliary switch block into the
connection point.
L+, C/Q, L-
Connection terminals for IO-Link and
A2-, A1+/Y1, Y2
auxiliary voltage and limit switch.
1L1, 3L2, 5L3
Connection terminals and main conductor on the line
2T1, 4T2, 6T3
side
and outgoing side.
DEVICE
Read the device status of the compact starter:
Device OK
Overload, process mapping error, general warning,
etc.
PRESET configuration not equal to ACTUAL
configuration
The LED indicates whether the main contacts are open
or closed.
SF
The LED indicates whether a group error is present.
TEST I>>
Press this button to test the short-circuit protection
function.
RLT 0%
Indicates either that the compact starter is in order or
there is a malfunction.
OFF: Compact starter is out of service.
READY: Compact starter is ready.
3)
2)
1)
1)
4)
1)
1)
SIRIUS 3RA6 compact starter
System Manual, 09/2014, NEB560060102000/RS-AA/006
1)
1)
1)
2)
1)