7. Settings / How to Use
7-1. PC-specific control software
Network IP Setting Tool
Execute : [Start] – Program – Samsung – LED Signage Manager – Network
Configuration
1.
Connect PC and Sbox with RS232C Cable, select connected
SerialPort(COM*). And click "open" button.
2.
Default ID of SBox is 1.
3.
Enter IP, SubnetMask, Gateway, DNS of S-box, and click "Apply"
button.
4.
Check the result of connection and status of MDC Protocol.
5.
When IP address is normally setup, "Change Type to RJ45" button is
appear. If LSM and SBox is connected successfully, click "Change Type
to RJ45". Then, PC connection with s-box is changed to RJ45 from
RS232.
[★ Cautions!] Recommend to use static IP address for the S-Box.
If DHCP is used, IP address is changed automatically and LSM can be
disconnected.
The 192.168.10.x band is used for internal communication of the LED Cabinet.
Please use IP another IP band (except 192.168.10.x band)
Do not assign the temporary IP, assign the S-Box IP (1 EA) through IT
manager.