6. S-Box Installation and Connection
• FPGA Update Guide when using Multi Link HDR Cable
※ Note : Before update, disconnect the Multi Link HDR Cable from S-BOX.
 Factory update method
① Save a SW program called 'TB-XCKUSBMWWS.bin' in
USB root.
② Connect the USB to S-BOX.
③ Enter Factory mode.
(Remote control 'mute +1+8+2+Power ON' in power off state)
④ Select "SVC → UPGRADE" menu.
⑤ Move the cursor to "FPGA UPGRADE" menu.
⑥ Press 'Enter' in the remote control.
⑦ Press '▶' button in remote control to start the upgrade.
※ Note : In case of the sites that are difficult to remove the Multi Link HDR cable, all connected S-BOX should be AC power off/on
after LSM update done. (Must turn off AC power after the update of all S-BOX are completed)
Check the version of FPGA after update.
(No support for SBB-SNOWJAU or below models)
 LSM update method
Select 'S-BOX Settings – Software Update' in LSM menu.
Select 'Browser' and move to the folder with the FPGA update file
(TB-XCKUSBMWWF.bin + Info.txt)
be higher than currently installed version
Select 'TB-XCKUSBMWWF.bin' file.
Select 'Update' button to start the upgrade.