4. Frame Installation
※ Precautions when tightening screws
Standard installation requirements by wall type
Check the wall type before installation.
Frames can be installed on a sufficiently thick concrete or
interior wall. Refer to the following figures.
At least 50 mm
Equipped with stiffeners,
e.g.
MDF or PW (plywood)
At least
50 mm
At least 10 mm
MDF, PW (plywood)
At least
25 mm
MDF, PW
Art Wall
(plywood)
(except the
plaster board
thickness)
At least
25 mm
Concrete
composite wall
(except the
plaster board
thickness)
First check the wall
specifications (e.g. type,
thickness, floor plan).
At least 30 mm
Wall
MDF, PW
(plywood)
At least 10 mm
MDF, PW (plywood)
If installing frames on a wall that is
not flat, irregular openings may
develop and affect the exterior
appearance.
At least 30 mm
Concrete
At least 10 mm
MDF, PW (plywood)
Sufficiently thick concrete or design wall
Wood stud inside a plaster board, or MDF wall
30
Installation requirements
Make sure you check the location of the wood stud
inside the wall before screwing screws into the wall.
Minimum wood stud size: 51 x 102 mm (2 x 4 inches)
Drill holes (3 mm) before screwing screws into the wall.
Make sure you drill screw holes in the middle of the
wood stud.
If you screw a screw directly into the wood stud without
drilling a hole, the wood may crack.
Standard wood stud interval of 16" is supported. (24" is
not supported.)
Samsung Electronics is not responsible for
problems caused as a result of failure to follow the
requirements specified in the installation guide.
LED R&D Lab(VD)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ier-f seriesIfr seriesIfr-f seriesLh0 ier ls seriesLh0 ier fs seriesLh0 ifr ls series ... Show all

Table of Contents