No.
Part name
Suction panel
1. Detachment
1) Remove the fixing screws A which fix the
2) Slide the suction panel to the arrow side
2. Attachment
1) Hook the suction panel to the fixing screws B
2) Attach the removed screws A to the original
Under air intake
Fixing screws A
AP005 Type
Suction panel
Fixing screws B
Back air intake
Fixing screws B
Fixing screws A
Electric parts
1. Detachment
box cover
1) Remove the screw A of the electric parts
2) As shown in the right figure, when sliding it
3) Take off the slit of the electric parts box
2. Attachment
1) Hook the slit of the electric parts box cover
2) Fix the electric parts box cover by
Procedure
suction panel. Loosen the fixing screws B.
and then remove the panel.
and tighten screws.
positions.
Fixing screws A
AP024 Type
Suction panel
Fixing screws B
Fixing screws B
Suction panel
Fixing screws A
box cover to loosen screw B.
toward arrow direction and pulling to this
side, the electric parts cover opens using
the hinge part as a shaft.
cover from the projection of the side plate
and then remove the cover.
to the projection of the side plate, close the
cover, enter screw B in the Key hole and
then slide it.
tightening with screws A and B.
AP036 Type
Suction panel
Suction panel
Suction panel
Fixing screws A
- 189 -
Remarks
Fixing screws A
Fixing screws B
Fixing screws B
Projection on the side plate
Slit
Side plate
Screw B
Key hole
Screw-A
Electric parts box cover
Hinge part