Battery

Use a hydrometer to test the battery. Charge the battery
if necessary (see Battery Service).
Electrolyte specific gravity
Fully charged: 1.250 - 1.280
Discharged: less than 1.240

Injection Pump (ETR) Solenoid

®
The Reelmaster
335-D has an energize-to-run (ETR)
fuel stop solenoid. The solenoid will stop injector pump
fuel delivery with any electrical failure in the RUN circuit.
1. Disconnect the wire from the solenoid.
2. Remove the solenoid from the injector pump.
3. Connect a 12 volt battery so that a wire from positive
(+) battery terminal is connected to switch terminal.
Touch a wire from the negative (–) battery terminal to
solenoid body. The plunger should retract.
NOTE: You can also test operation without removing the
solenoid from the injector pump. Listen for an audible
"click" as the solenoid extends and retracts while doing
step 3 of the above procedure. This will not show if the
solenoid is fully extending and retracting.