Testing
This section will define components, and the tests that
can be performed on those components, when those
parts are disconnected from the electrical system.
For accurate resistance and/or continuity checks,
electrically disconnect the component being tested from
the circuit (e.g. unplug the seat switch connector before
doing a continuity check).
NOTE: Electrical troubleshooting of any 12 Volt power
connection can also be performed through voltage drop
tests without disconnection of the component.
Ignition Key Switch
The ignition (key) switch has three positions (OFF, RUN
and START). The terminals are marked as shown.
The circuitry of the ignition switch is shown in the chart.
With the use of a continuity tester, the switch functions
may be tested to determine whether all circuits are being
completed while the key is moved to each position.
®
Reelmaster
335-D
When testing electrical components for con
tinuity with a volt-ohm meter or continuity
tester, make sure that power to the circuit has
been disconnected.
POSITION
1. OFF
2. RUN
3. START
Page 5 - 15
CAUTION
A
Y
B
S
I
X
Figure 4
CONTINUITY
OTHER
AMONG
CIRCUITS
TERMINALS
MADE
NONE
B + I + A
B + I + S
Figure 5
NONE
X + Y
NONE
Testing