3-11. BLOWER MOTOR
REPLACEMENT
Figure 3-1
Figure 3-2
Figure 3-3
Figure 3-4
Feb. 2011
To avoid electrical shock or property damage, move
the POWER switch to OFF and disconnect main
circuit breaker, or unplug cord at wall receptacle.
1. Remove module top per paragraph 3-10.
2. Unplug wires to blower motor. Figure 3-1.
3. Using a Phillip's head screwdriver, remove the screws
securing the blower bracket to the module. Figure 3-2.
4. Pull bracket from module. Loosen set screw on fan
blade and pull blade from blower. Figure 3-3.
5. Remove the 3 nuts securing the blower to the bracket
and remove blower motor. Figure 3-4.
6. Install new blower in reverse order, and unit is now
ready for use.