Main Power Switch - Henny Penny Wendy’s Evolution Elite EEG-153 Service Manual

Reduced oil capacity open gas fryer
Table of Contents

Advertisement

6-5. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)

6-6. MAIN POWER SWITCH

May 2012
7. Using an 11/16" crows-foot remove the large high limit
fitting in vat wall, and pull the high limit from inside the
control area.
8. Install new high limit in reverse order and restore power to unit.
9. Fill vat by pressing and holding
*MENU* shows in the display. Then once "1.EXPRESS
FILTER" shows in the display, press ► 4 times until
"5.FILL FROM PAN" shows in the display. Press √ button
and "PUMP" "EXIT" shows in the display. Press √ button
again, and oil fills vat. Once vat is full, press X twice to return
to normal operation.
This is a covered rocker switch, which in the ON position,
sends power to all the controls and filter motor.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove right side panel.
2. Label and remove wires from the switch.
3. From the inside of the control area, squeeze in on the tabs
on the back of the switch and push the switch out the front
of the control area.
Checkout
4. Check across the two sets of terminals of the switch for
continuity. With the switch in the ON position, the circuit
should be closed. With the switch in the OFF position, the
circuit should be open.
If the switch is found to be defective, replace it by connecting
the wires to it (as labeled) and push new switch into place.
6-5
Model EEG-153, 154
button until *FILTER*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wendy’s evolution elite eeg-154

Table of Contents