Removing And Installing The Storage Server Fan - IBM TotalStorage FAStT700 User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT700:
Table of Contents

Advertisement

Attention:
To prevent damage to the FAStT700 Storage Server components,
do not operate the FAStT700 Storage Server without adequate ventilation to the
controllers. If it will take longer than 15 minutes to replace the storage server
fan, you must shut down the FAStT700 Storage Server to prevent it from
overheating. The time limit applies to the total time that the fan is out of the
chassis. For more information, see "Turning off the power" on page 19.
2. Remove the failed storage server fan, as shown in Figure 39.
a. Lift up the lever on the storage server fan.
b. Pull firmly on the bottom lip to remove the fan.
Storage server
fan lever
Figure 39. Removing and installing the storage server fan
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling static-sensitive
devices, see "Handling static-sensitive devices" on page 35.
3. Unpack the new storage server fan.
4. Install the new storage server fan.
a. Slide the new storage server fan all the way into the slot.
b. Press down on the lever and snap the lever into place.