Mini Hubs; Servicing Notes; Replacing A Failed Mini Hub - IBM TotalStorage FAStT700 User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT700:
Table of Contents

Advertisement

Mini hubs

The mini hubs are located on the back of the FAStT700 Storage Server (see
Figure 50 on page 57). A mini hub is a single, removable unit that provides the Fibre
Channel interface between a FAStT700 Storage Server and hosts or drives. The
back of the FAStT700 Storage Server can accommodate eight mini hubs: up to four
host-side and up to four drive-side mini hubs. Each mini hub has two ports. An SFP
module is installed in a mini-hub port; then, a fiber-optic interface cable is
connected into the SFP module. For more information, see "Fibre Channel
connections" on page 2 and "Small Form-Factor Pluggable (SFP) Modules" on
page 52.

Servicing notes

Consider the following when servicing mini hubs:
v You can hot swap (replace) a failed mini hub while the FAStT700 Storage Server
v Four indicator lights provide status information. If a mini hub fails, the interface
v If you replace the mini hub and the SFP modules in them and still experience
For more information, see "Fibre Channel connections" on page 23 and "Interface
ports" on page 125.

Replacing a failed mini hub

When instructed by the storage-management software, replace a mini hub. Use the
following procedure to replace either a failed host-side or drive-side mini hub.
Attention:
that has not failed.
Note: You must remove the fiber-optic cable from the SFP module before you can
1. On the mini hub that has failed, remove the fiber-optic cables from the SFP
®
56
IBM
TotalStorage
FAStT700 Fibre Channel Storage Server: User's Guide
is in operation.
fault and the bypass indicator lights on the mini hub are lit and the loop good
indicator light is off. For more information about indicator lights, see "Mini-hub
indicator lights" on page 27.
problems, the FAStT700 Storage Server might have defective components or
connections. Check the storage-management software for indications of other
component failures.
To prevent possible data loss, do not remove cables from a mini hub
remove the SFP module from the mini-hub port.
modules, as shown in Figure 49 on page 57.
For proper handling of fiber-optic cables, see "Handling fiber-optic cables" on
page 3.

Advertisement

Table of Contents
loading

Table of Contents