Using the Visual Fault Locator

The fiber module includes a visual fault locator that helps
you quickly check fiber continuity, trace fibers, and locate
faults along fibers and in connectors.
The visual fault locator port accepts connectors with
2.5 mm ferrules (SC, ST, or FC). To connect to other ferrule
sizes, use a patch cord with the appropriate connector at
one end and a SC, ST, or FC connector at the tester end.
Figure 14 shows the equipment needed for using the
visual fault locator.
PASS
TEST
FAIL
TALK
TONE
LOW BATTERY
F1
F2
F3
EXIT
TEST
ENTER
SAVE
AUTO
TEST
SINGLE
SETUP
TEST
SPECIAL
MONITOR
FUNCTIONS
TEST
TALK
TALK
1
A
Tester or smart remote with fiber module
B
AC adapter with line cord (optional)
C
One patch cord. Match fiber and connectors to be
tested; SC, ST, or FC at tester end. (optional)
D
Fiber cleaning supplies
Figure 14. Equipment for Using the Visual Fault Locator
Using the Visual Fault Locator
3
2
4
amd61f.eps
33