Fluke DTX-MFM User Manual page 24

Fiber modules
Hide thumbs Also See for DTX-MFM:
Table of Contents

Advertisement

DTX-MFM/SFM Fiber Modules
Users Manual
Autotest in Smart Remote Mode
1
Turn on the tester and smart remote and let them sit for
5 minutes. Allow additional time if the modules have
been stored above or below room temperature.
2
Turn the rotary switch to SETUP, then select Fiber. Set
the following on the Fiber tabs (press
tabs):
Fiber Type: Select the fiber type to be tested.
Test Limit: Select the test limit required for the job. Press
J
More to see other lists of limits.
Remote End Setup: Set to Smart Remote.
Bi-directional: Enable this if you are required to test the
fiber in both directions.
Number of Adapters and Number of Splices: Enter the
number of adapters and splices that will be added to
each direction of the fiber path after the reference is
set.
18
Connector Type: Select the connector type used in the
cabling to be tested. Select General if the exact type is
not listed.
Test Method: Refers to the number of adapters
C
to see other
represented in the loss results. Select Method B if you
use the reference and test connections shown in this
manual.
3
Turn the rotary switch to SPECIAL FUNCTIONS, then
select Set Reference. If both a fiber module and twisted
pair adapter are attached, select Fiber Module next.
4
The Set Reference screen shows reference connections
for the test method you selected. Figure 6 shows
connections for Method B. Clean the connectors on the
testers and patch cords, connect the tester and smart
remote; then press
See Table 2 on page 12 for details on settings.
P
.
-continued-

Advertisement