Figure 18 Fact. Mounted T-Stat "1" & "3" Opt - Bard QW Series Installation Instructions Manual

Geothermal r-410a staged capacity packaged heat pump
Hide thumbs Also See for QW Series:
Table of Contents

Advertisement

Temperature/Humidity Control "1" & "3" Option Wiring Diagram
D
SC
7
A
W2
W1/E
SC
7
Y2
Y1
Y0
SC
7
O/B
G
24V
COM
L
GND
COMPLETESTAT TEMPERATURE,
HUMIDITY, AND OCCUPANCY
CONTROLLER.
BARD PART# CS9B-THO
OR CS9BE-THO
Manual 2100-577C
Page
24 of 50
Factory-Mounted Completestat™ with Occupancy Sensing and
Black/White
8
Gray
8
Gray
2
FIGURE 18
Purple/White
Brown/White
Brown
Red/Yellow
Purple
Yellow
Blue
Orange
Red/White
Black/White
Pink
COM
NO
NC
ALARM RELAY
5
Plug #2 9
1
5
9
3
4
7
8
6
10
11
12
4115-108