7
Load Dial
LOAD
A1
1/2
Figure 6. 440V overload relay set at 7 amps.
Replace the control panel before connecting
4.
the jointer to power.
Replacing Control Panel Light Bulbs
DISCONNECT JOINTER FROM POWER!
1.
Remove the control panel from the electrical
2.
pedestal to access the rear of the power lamp
and ON button assemblies (see Figure 7).
Button Assembly
Lock Latch
Figure 7. Accessing the light bulb from the rear
of the control panel.
-12-
TECO
O/L Relay
RHN-10
A2
95
96
98
3/4
5/6
Use a small, flat screwdriver to move the
3.
power lamp assembly lock latch to the left, as
shown in Figure 7, pull the assembly loose
from the panel, then replace the light bulb.
Re-install the lamp assembly, move the lock
4.
latch to the right to secure it.
Repeat Steps 3–4 for the ON button, then
5.
re-install the control panel onto the electrical
pedestal.
Rewiring Motor
DISCONNECT JOINTER FROM POWER!
1.
Remove the rear motor access panel, then
2.
remove the motor wiring junction box cover.
Configure the terminal jumpers as shown in
3.
Figure 8.
Terminal
Jumper
Ground
Figure 8. Illustration of motor wired for 440V
operation.
Replace the motor junction box cover and
4.
access panel before connecting the jointer to
power.
Extreme Series Jointer (Mfd. Since 10/20)
4
5
6
7
8
9
1
2
3