6.4
























EN-22
Activation of special functions
By activating this function, the circulation pump is
switched on constantly for a period of 24 hours.
The heat pump remains blocked during this period.
Automatic program for targeted heat drying of
screed floors
Sets the maximum return flow temperature to be
reached during initial heating.
Selecting this function will permit any request for
domestic hot water or swimming pool water during
initial heating.
Activates the initial heating program.
Activates the standard program for screed drying.
Sets the duration of the individual steps during the
heating-up phase.
Sets the maintaining time.
Sets the duration of the individual steps during the
heating-down phase.
Sets the temperature difference between the two
steps in the heating-up phase.
Sets the temperature difference between the two
steps in the heating-down phase.
Activates the individual program for screed drying.
Function for the heating technician
Display
No
Circulation
Yes
Always
25 °C
Always
... 35 °C ...
50 °C
No
Always
Yes
No
Always
Yes
No
Always
Yes
1
Always
... 24...
120
1
Always
... 24...
480
1
Always
... 24...
120
1K
Always
... 5K...
10K
1K
Always
... 5K...
10K
No
Always
Yes
Always